Origin |
Guangdong Province, China |
Model Number |
JLG20-BV8 |
Gas Boiler Series
Main Features:
1>.Low circulation water pressure protection: Minimum 0.5Mpa.
2>.Hot water temperature exceptional protection: Maximum 3℃/sec.
3>.Anti-frequently start ignition: An interval 3 minutes between next start.
4>.Multiple frost protection:
(A)≤8℃pump circulate 30min.
(B)≤5℃heating for 5min.
(C)lgnition fail no gas supply, pump circulate 24hrs
5>.Lighting strike protection.
6>.Deflagration protection: Increase gas flow automatically when gas pressure too low (lgnition time exceptional).
7>.Anti-lock water pump: 30 sec./24hrs. circulate automatically during summer.
8>.Ultra quite operation: C.E. approved motor fan and pump.
9>.Self-diagnostic: Resume work from simply breakdown.
10>.Multifunctional user interface:
(A) Max.~ Min. gas flow control.
(B) The circulation water temperature difference control between outlet and return water.
(C) Hot water temperature exceptional protection control.
11>.Switch radiator heating and under floor heating.
12>.Switch water pump between 3 min. circulatinig after intermittence 8 min. and 24 hrs during stand by.
13>. Adustable the circulation water temperature difference between outlet and return water (10~30) during stand by.
14>.Domestic hot water priority function.
15>.Avoid to rising temperature of domestic hot water when re-start tap by circulating hot water automatically after turn off the tap.
16>.20sec. exhaust waste gas before and after combustion
(3 sec. For domestic hot water funtion).
17>.Technical Parameters:
| Model |
Unit |
JLG20-BV8 |
| Rated Heat Input |
Kw |
20 |
| Rated Output Power |
Kw |
18 |
| Heat Efficiency |
% |
>90 |
| Max Power Input |
w |
125 |
| Power Supply |
|
AC220V/50HZ |
| N.W. |
Kg |
37 |
| External Dimensions |
mm |
740X430X248 |
| Index Of Protection |
IP |
IPX4 |
Gas Type Gas Pressure Gas Consumption |
LPG |
Rated Gas Pressure |
Pa |
2800 |
| Gas Consumption |
Nm3/Kwh |
0.035 |
| NG |
Rated Gas Pressure |
Pa |
2000 |
| Gas Consumption |
Nm3/Kwh |
0.1 |
| Central Heating |
Output Power Range |
Kw |
5.4~18 |
| Water Temperature Range |
℃ |
40~80 |
| Reference Heating Square |
m2 |
90~130 |
| Water Working Pressure Range |
Bar |
0.8~2.7 |
Heating Return Safety Valve Opening Water Pressure |
Bar |
3 |
| Pump Lift |
M |
6 |
| Expansion Vessle Capacity |
L |
6 |
DHW (Domestic Hot Water) |
Output Power Ranger |
Kw |
5.4~18 |
| DHW Temperature Set Range |
°C |
<65 |
| Max DHW Output △t=25K |
Kg/min |
10 |
| Operation Pressure DHW Range |
Bar |
0.3~7 |
| Fittings |
Central Heating Fittings |
Inch |
G3/4 |
| DHW Fittings |
Inch |
G1/2 |
| Gas Fittings |
Inch |
G3/4 |
| Coaxial Flue Pipe |
Straight |
mm |
F60/100 |
| |
Elbow |
mm |
F60/100 |
Max Permissible Flue Lengths |
Max Horizontal Flue Length (100cm) |
cm |
95cm |
| Max Vertical Flue Length (100cm) |
cm |
14cm |
Flue Pipe Length Reduction For Elbows |
90° Elbow F60/100mm |
m |
1.0m |
| 45° Elbow F60/100mm |
m |
0.5m |
|